Part numbers and specifications:
WILL FIT THESE CABLES | PANEL DIMENSIONS | PART NO. | DESC. | PART DIMENSIONS | Mounting Hole Plug | CAD |
UL Type | AWG/ Conductors | Approximate Size | A Mounting Hole Dia. | B To Prevent Rotation | Finished Fit Panel Thickness* | Black | C HEAD LENGTH | D BODY LENGTH |
mm. | mm. | mm. | mm. | mm. | mm. | PART NO. |
For Flat Cables |
SPT-1 | 18/3 | 3,0x7,6 | 12,7 | 11,8 | 1,6 | 1541 | SR 4N-7 | 43,6 | 50,4 | 2491 |  |
SPT-2 & HPN | 18/2 | 3,8x7,1 |
For Round Cables |
SV & SVT | 18/2 | 6,4 | 12,7 | 11,4 | 1,6 | 1590 | SR 5N-7 | 43,3 | 50,4 | 2491 |  |
18/3 | 6,5 | 12,7-13,1 |
HPD | 18/2 | 6,9 | 12,7 |
16/2 | 7,4 | 12,7-13,1 |
Same as SR 5N-7 above except –––––––––––––––––––––––––––––––––––––––––––> | 3,2 | 1593 | SR 5P-7 | 43,3 | 50,4 | 2491 |  |
SJ, SJO & SJT | 18/2 | 7,6 | 15,9 | 14,0 | 1,6 | 1596 | SR 6N-7 | 43,6 | 53,6 | 2497 |  |
Same as SR 6N-7 above except –––––––––––––––––––––––––––––––––––––––––––> | 3,2 | 1602 | SR 6P-7 | 43,6 | 53,6 | 2497 |  |
SJ, SJO & SJT | 16/2 | 8,0 | 15,9 | 14,0 | 1,6 | 1599 | SR 6N3-7 | 43,6 | 53,6 | 2497 |  |
18/3 | 8,1 |
14/2 | 8,9 |
16/3 | 9,0 |
18/4 | 9,1 |
Same as SR 6N3-7 above except –––––––––––––––––––––––––––––––––––––––––––> | 3,2 | 1605 | SR 6P3-7 | 43,6 | 53,6 | 2497 |  |
1604 | SR 6P3-7S** |
SJT | 18/4 | 9,1 | 19,0 | 16,8 | 3,2 | 1611 | SR 7P-7 | 54,9 | 66,0 | 2503 |  |
SJT & SJTO | 14/3 | 9,4 |
S & ST | 18/2 | 9,9 |
18/3 | 10,3 |
16/2 | 10,3 |
16/3 | 10,9 | 19,0-19,8 |

Standard color black. Consult Heyco for white and other colors. *Maximum Panel Thickness. Part has additional clearance. Consult Heyco for your Custom Finished Fit Panel Thickness. **For use in split housings only: Larger locking step on body and key, for additional pull out resistance.